Hydram pump is one type of pump that does not require electricity or fuel. Potential energy from water sources that is channeled as a driving force. Where this tool works at a source of water that has a slope, because this tool requires water flow energy from a height greater than or equal to 1 meter into the pump. In the operation of this pump has the advantage of using PVC pipes which are simple to design can also be made with workshop equipment. This research was conducted to determine the effect of variations in the distance between the waste valve and the delivery valve on the efficiency of the hydram pump. The method used is a real experimental with some changes in the variation of the distance between the waste valve and the delivery valve is 10 cm, 20 cm, 30 cm. From the results of the study that the optimum pumping discharge increased in the short size of 0.00011633 m3 / second, the greater the discharge of waste at a long-distance size of 0.00086013 m3 / second, with the number of beats occurring at 84 times. So that the efficiency of hydrams according to the theory of 'aubussion obtained the highest yield of 71.02%.
Real Time Impact Factor:
Pending
Author Name: Defmit B.N Riwu, Dominggus G. H. Adoe, Seprianus Rudolf Membubu
URL: View PDF
Keywords: 2-inch hydram pump, double valve waste, delivery valve, and D'obuission efficiency.
ISSN: 2503-5274
EISSN: 2657-1900
EOI/DOI: https://doi.org/10.35508/fisa.
Add Citation
Views: 1